Single Reader / One-Door Access Control Interface
📌 Overview
The Mercury MR50 Interface Module is a compact single-reader interface module designed to manage one door within a Genetec Synergis™ access control system.
It connects to Mercury intelligent controllers over RS-485 communication and provides real-time monitoring and control via Synergis Cloud Link and Security Center.
🚀 Key Features
- Controls 1 door (single reader configuration)
- Supports OSDP v1 & v2 readers
- Real-time event reporting
- RS-485 high-speed communication
- Compact footprint for panel installations
- UL 294 recognized
- Supervised inputs for monitoring
- Flexible I/O capabilities
⚙️ Interfaces & I/O
🔹 Readers
- 1 reader port
- Supports 1 reader (entry only)
🔹 Inputs
- 2 programmable general-purpose inputs
- 1 dedicated tamper input
🔹 Outputs
- Relay 1: Form C, 5A @ 30V DC
- Relay 2: Form C, 2A @ 30V DC
🧠 System Architecture
The MR50 is deployed as part of a distributed Mercury system:
- Connected to Mercury Controllers (EP1502 / EP2500 / EP4502)
- Communication via RS-485 bus
- Managed through Synergis Cloud Link (IP layer)
- Integrated into Genetec Security Center
This architecture ensures scalable and reliable access control deployment.
🌐 Integration with Genetec
Fully compatible with:
- Genetec Security Center
- Synergis™ IP Access Control
- Synergis Cloud Link appliance
This enables centralized management, real-time monitoring, and seamless system expansion.
📊 Technical Specifications
| Parameter | Specification |
|---|---|
| Doors Supported | 1 |
| Readers | 1 |
| Communication | RS-485 (2-wire, up to 4000 ft) |
| Inputs | 2 + 1 tamper |
| Outputs | 2 relays |
| Operating Temp | -40°C to 75°C |
| Storage Temp | -55°C to 85°C |
| Dimensions | 70 × 108 × 25.4 mm |
| Certifications | UL 294, CE, RoHS |
🔒 Reliability & Compliance
- UL 294 recognized hardware
- Industrial-grade design
- 24-month warranty
- Built for secure, non-proprietary access control systems
🏢 Typical Use Cases
- Single-door access control points
- Small secure rooms or cabinets
- Expansion of existing Mercury systems
- Cost-efficient door control deployments
⚠️ Installation Notes
- Requires connection to a Mercury Intelligent Controller
- Follow proper RS-485 wiring and termination
- Ensure stable power supply and grounding
- Recommended to use OSDP secure channel
📞 Need Technical Assistance?
For configuration, wiring, or troubleshooting:
👉 Contact Aligntech Technical Assistance Services (TAS)